    Exposed steel and voids at the slab edge

    Concrete slab or driveway damage, holes or poor finish turned up in 19% of homes at handover.

    Exposed steel and voids at the slab edge
    Found at a recent handover inspection.
    Exposed steel and voids at the slab edge
    Found at a recent handover inspection.

    What it is

    Steel reinforcement showing at the slab edge, with open voids (honeycombing) in the concrete.

    Why it matters

    Steel needs concrete cover to stop it rusting. Once it rusts it swells and cracks the concrete around it, which is known as concrete cancer.

    How we check it

    At slab stage we check the edge for voids, honeycombing and exposed bars, and that the concrete has been properly compacted.

    The fix

    Rework the slab edge to restore full cover to the steel, as set out in the report.

    How common it is

    Concrete slab or driveway damage, holes or poor finish turned up in 19% of homes at handover.

    The standard

    ABCB Housing Provisions 2022, 4.2.11(5); AS 2870